LMN-PowerEye

LMN-PowerEye

12 V LMN test, measurement and load system

LMN-PowerEye is used to test the LMN (local metrological network) behaviour of smart meter gateways (SMGw) under defined load conditions. The system acquires voltage, current and power on the SMGw and meter side and provides a software-controlled additional load.

The system is intended for laboratory, integration and field tests in a 12 V LMN environment. It is not a universal high-power electronic load and is not intended for billing subject to legal metrology (eichpflichtige Abrechnung).

It is supplied as a complete system: control/measurement module with display, additional load module, LMN cables, connection leads and RS-485 cable set. It is controlled by PC software via RS-485 (Modbus RTU).

Request a quote

Placed on the EU market by: DIINNO GmbH, Brunsbütteler Damm 93, 13581 Berlin, Germany

We sell exclusively to businesses (entrepreneurs within the meaning of Section 14 of the German Civil Code, BGB), legal entities under public law and special funds under public law. No sales to consumers.

Product selection

Configure your request – choose your options and click “Request a quote”. Your email program opens with your selection.

Version
Quantity (pcs)
Intended use
Comment

Your email program opens with your selection – you can review and add to the request before sending.

Versions compared

All versions use the same control/measurement module. They differ in the additional load module and the supplied PC adapter.

Attribute LMN-PowerEye-S without load module LMN-PowerEye-L with load module LMN-PowerEye-X with load module and PC adapter
Control/measurement module 1 ×1 ×1 ×
Additional load module incl. connection leads L+ / L− –1 ×1 ×
LMN-USB12V incl. RS-485 cable set ––1 ×
LMN cable 2 ×2 ×2 ×
Main application Measuring the LMN bus parametersadditionally testing under defined loadadditionally direct connection to the PC

Scope of delivery according to packing list PL-LMN-POWEREYE-DE (as of 07/2026), which states for each item which version it belongs to.

Technical features

Features

  • Display of voltage, current and power on the SMGw and meter side
  • Software-controlled additional load, adjustable 1–4 W; continuous operation up to 3.5 W recommended
  • Cyclic acquisition and control via PC software (RS-485, Modbus RTU)
  • DIN-rail mounting: compact control/measurement module and separate additional load module
  • Complete system incl. LMN cables, connection leads and RS-485 cable set

Technical data

Product type
12 V LMN test, measurement and load system
Nominal system voltage
12 V DC
Adjustable additional load
1–4 W (via software)
Recommended continuous operation
up to 3.5 W
Short-term measurement
up to 4 W
Load branch protection
500 mA
LMN/RJ12 branch
max. 500 mA / 6 W at 12 V
Max. input power (both branches)
approx. 10 W
LMN interfaces
2 × RJ12 (gateway/SMGw and smart meter)
PC/bus interface
RS-485, Modbus RTU
Device address
1–254
Default baud rate
115200 bit/s
Control/measurement module (W × H × D)
approx. 27 × 95 × 18 mm
Load module (W × H × D)
52.5 × 90 × 54.5 mm
Mounting
DIN rail
Form of delivery
complete system
Marking
CE; not for billing subject to legal metrology

Documents

All documents open directly in the browser and can be saved if required.

  • Datasheet LMN-PowerEye (German) PDF · 3 pages · as of 07/2026 Open
  • Product manual (German) PDF · 7 pages · connection, commissioning and operation Open
  • Software manual (German) PDF · 9 pages · operating the PC software Open

Software

Control and measurement software for Windows (operation via RS-485 / Modbus RTU). The software is of no use without the LMN-PowerEye hardware; the download is freely available.

  • DIINNO PowerEye Host v1.0.6 (Windows) Windows · ZIP approx. 95 MB · unzip and run Download

Tender text

Short text for use in bills of quantities.

LMN-PowerEye – 12 V LMN test, measurement and load system for testing the LMN behaviour of smart meter gateways under defined load conditions. Acquisition of voltage, current and power on the SMGw and meter side. Software-controlled additional load 1–4 W (continuous operation up to 3.5 W recommended). Two LMN interfaces (2 × RJ12) for gateway/SMGw and smart meter. Control and cyclic acquisition of measured values via PC software over RS-485 (Modbus RTU), device address 1–254, baud rate 115200 bit/s. Version for DIN-rail mounting consisting of a control/measurement module with display (approx. 27 × 95 × 18 mm) and a separate additional load module (52.5 × 90 × 54.5 mm). Supplied as a complete system incl. LMN cables, connection leads and RS-485 cable set. Marking CE; not for billing subject to legal metrology. Make: DIINNO GmbH or equivalent.

Catalogue Email LinkedIn